NAME
logger — log
messages
SYNOPSIS
logger |
string ... |
DESCRIPTION
The logger utility saves a message, in an
unspecified manner and format, containing the string
operands provided by the user. The messages are expected to be evaluated
later by personnel performing system administration tasks.
It is implementation-defined whether messages written in locales other than the POSIX locale are effective.
OPTIONS
None.
OPERANDS
The following operand shall be supported:
- string
- One of the string arguments whose contents are concatenated together, in the order specified, separated by single <space>s.
STDIN
Not used.
INPUT FILES
None.
ENVIRONMENT VARIABLES
The following environment variables shall affect the execution of
logger:
LANG- Provide a default value for the internationalization variables that are unset or null. (See the Base Definitions volume of IEEE Std 1003.1-2001 (“POSIX.1”), Section 8.2, Internationalization Variables for the precedence of internationalization variables used to determine the values of locale categories.)
LC_ALL- If set to a non-empty string value, override the values of all the other internationalization variables.
LC_CTYPE- Determine the locale for the interpretation of sequences of bytes of text data as characters (for example, single-byte as opposed to multi-byte characters in arguments).
LC_MESSAGES- Determine the locale that should be used to affect the format and contents
of diagnostic messages written to standard error. (This means diagnostics
from
loggerto the user or application, not diagnostic messages that the user is sending to the system administrator.) NLSPATH- [
XSI] Determine the location of message catalogs for the processing of LC_MESSAGES .
ASYNCHRONOUS EVENTS
Default.
STDOUT
Not used.
STDERR
The standard error shall be used only for diagnostic messages.
OUTPUT FILES
Unspecified.
EXTENDED DESCRIPTION
None.
EXIT STATUS
The following exit values shall be returned:
CONSEQUENCES OF ERRORS
Default.
APPLICATION USAGE
This utility allows logging of information for later use by a system administrator or programmer in determining why non-interactive utilities have failed. The locations of the saved messages, their format, and retention period are all unspecified. There is no method for a conforming application to read messages, once written.
EXAMPLES
A batch application, running non-interactively, tries to read a configuration file and fails; it may attempt to notify the system administrator with:
logger myname: unable to read file foo. [timestamp]
RATIONALE
The standard developers believed strongly that some method of alerting administrators to errors was necessary. The obvious example is a batch utility, running non-interactively, that is unable to read its configuration files or that is unable to create or write its results file. However, the standard developers did not wish to define the format or delivery mechanisms as they have historically been (and will probably continue to be) very system-specific, as well as involving functionality clearly outside the scope of this volume of IEEE Std 1003.1-2001 (“POSIX.1”).
The text with LC_MESSAGES about diagnostic
messages means diagnostics from logger to the user
or application, not diagnostic messages that the user is sending to the
system administrator.
Multiple string arguments are allowed, similar to echo(1), for ease-of-use.
Like the utilities mailx(1) and
lp(1), logger is admittedly
difficult to test. This was not deemed sufficient justification to exclude
these utilities from this volume of IEEE Std 1003.1-2001
(“POSIX.1”). It is also arguable that they are, in
fact, testable, but that the tests themselves are not portable.
FUTURE DIRECTIONS
None.
SEE ALSO
CHANGE HISTORY
First released in Issue 4.
End of informative text. footer end